Homepage | Home | Bookmarke
Member

Suzhou Lanscientific Instrument Co. Ltd.


Products
  • No Category
Search
 

Friends links
  • No link
You are here: Home » Products » Offer SP-3520AA Atomic Absorption Spectrophotometer
Offer SP-3520AA Atomic Absorption Spectrophotometer
Click image to view full size image
Product: Views:140Offer SP-3520AA Atomic Absorption Spectrophotometer 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-09-28 15:49
  Inquiry
Details
Main Technical Parameters Optical System 1.Instrument type single beam reflection achromatic optics system. 2.Monochrometer: achromatic C-T. 3.Bandwidth (nm): 0.1.0.2,0.7,1.4nm adjustable. 4.Wavelength range (nm): 190-900. 5.Wavelength accuracy (nm): ±0.20 . 6.Wavelength repeatability (nm): ≦0.10 . 7.Resolution better than 0.3nm (Mn 279.5nm and 279.8nm peak valley≦30% . Spectrophotometer Properties 1.Measurement: A.T.C 2.Photometric range: 0-125%,-0.1-3.00A 3.Static baseline drift (Cu):±0.003A/30min 4.Dynamic baseline drift (Cu):±0.004A/30min 5.Background correction:D-lamp background correction, self-absorbance background correction>50 times correction ability (1Abs) 6.Atomization system: flame and graphite furnace Flame 1.Characteristic concentration: (Cu)≦0.03μg/mL/1% 2.Detection limit: (Cu)≦0.006μg/mL 3.Precision: RSD≦1% 4.Burner: titanium 5.Nebulizer: height-efficient glass nebulizer 6.Spray chamber: anticorrosion material 7.Safety measures: flame fuel gas, power assisted gas abnormal pressure protection. Graphite Furnace 1.Characteristic quantity characteristic value: Cd≦0.5*10-12g 2.Detection Limit characteristic value: Cd≦1.0*10-12g 3.Precision: Cd≦3% 4.Test manner: flame, graphite furnace, hydride-AA, flame emission Data Process 1.Concentration: standard curve, standard addition, interpolation 2.Times of repetitive measurement: 1-30times, average value of A&C 3.QA/QC: relative coefficient, abs. Concentration SD, RSD, analysis data electronic document export is feasible. 4.Data output: test data could be saved as original record form through pro-software 5.Report print: parameters, data result, graph 6.Data interface: standard RS-232 interface Instrument functions 1.Instrument setup D-lamp background correction auto-adjust optics beam device 2.Automatic wavelength scan, peak seeking band width adjust 3.Automatic ignite adjust negative high voltage 4.Lamp current, balance two beams, flameout protection. More details please contact Miss Jackie at lanscientific[at]gmail[dot]com! Suzhou Lanscientific Instrument Co. Ltd. Mobile: +86-18962124052 E-mail: lanscientific[at]gmail[dot]com Skype: lanscientific
Inquiry